Overview

The SR50 measured elapsed time between emission and return of an ultrasonic pulse. An independent air temperature measurement was required. The SR50 output SDI-12, pulse train, or serial ASCII. Output options were configured with internal jumpers.

The "-L" on a product model indicates that the cable length is specified at the time of order.

Images

Specifications

Power Requirements 9 to 16 Vdc
Measurement Time 0.6 s (typical)
Measurement Range 0.5 to 10 m (1.6 to 32.8 ft)
Accuracy ±1 cm (0.4 in.) or 0.4% of distance to target (whichever is greatest)
Operating Temperature -45° to +50°C
Diameter 7.5 cm (3 in.)
Length 31 cm (12.2 in.)
Weight 1.3 kg (2.9 lb)

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
21X (retired) The 21X is compatible only with the pulse train output.
CR10 (retired) The CR10 requires a special PROM to measure the SDI-12 output.
CR1000 (retired)
CR10X (retired)
CR200X (retired) The CR200X-series is only compatible with the SDI-12 output.
CR206X (retired) The CR200X-series is only compatible with the SDI-12 output.
CR211X (retired) The CR200X-series is only compatible with the SDI-12 output.
CR216X (retired) The CR200X-series is only compatible with the SDI-12 output.
CR23X (retired)
CR295X (retired) The CR200X-series is only compatible with the SDI-12 output.
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR850 (retired)
CR9000 (retired) The CR9000 is compatible only with the pulse train output.
CR9000X (retired) The CR9000X is compatible only with the pulse train output.

Additional Compatibility Information

Data Logger Considerations

SDI-12 and pulse train output options are available for measuring the SR50.

Case Studies

New Mexico: Meteorological Monitoring at a Mine
Chevron Mining, Inc., (CMI) owned and operated a 6.6 million-metric-ton-per-year (6.6 million-U.S.-ton) molybdenum mining and......read more
Alaska: Eddy Covariance
Scientists and land-use managers have long recognized the importance of forest lands for their role......read more
Delaware: Environmental Observing System
The Delaware Environmental Observing System (DEOS) is a real-time system dedicated to monitoring environmental conditions......read more

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences