As a non-contact, radar water-level sensor, you can use the RangeVue™️30 to monitor the water level of rivers, lakes, and reservoirs. With 80 GHz radar technology, the RangeVue 30 directly measures the distance between the sensor face and the water surface. This distance can be used to determine water level or stage. The sensor is ideal for areas where submersible sensors can be damaged due to corrosion, contamination, flood-related debris, or lightning. 

Benefits and Features

  • Non-contact water-level measurement
  • Meets United States Geological Survey (USGS) Office of Surface Water (OSW) requirements for accuracy
  • SDI-12 version 1.4 functionality
  • Configurable over SDI-12
  • Bluetooth-configurable over smartphone, tablet, or PC

Images


Specifications

Measurement Description Distance
Output Options SDI-12
Measurement Range 30 m (98.4 ft)
Accuracy ±2 mm (±0.0065 ft)
Resolution 1 mm (0.0033 ft)
Radar Frequency W-band (80 GHz)
Beam Angle
Input Voltage 8 to 30 Vdc
Current Drain 10 mA (at 12 Vdc)
Operating Temperature Range -40° to +80°C
Mechanical Rating IP66/68 IEC 60529, Type 4X/6P UL 50
Material PVDF, FKM
Cable Termination 4-Pin A-Coded M12 Connector
Threads 1 NPT

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
CR1000 (retired)
CR1000X
CR200X (retired)
CR295X (retired)
CR300
CR3000 (retired)
CR310
CR350
CR6
CR800 (retired)
CR850 (retired)

Communication Devices

Product Compatible Note
AL200

Miscellaneous

Product Compatible Note
Granite 6

Additional Compatibility Information

The RangeVue 30 interfaces using the SDI-12 communications protocol, and it is compatible with any SDI-12-compliant data recorder, including Campbell Scientific data loggers.

Downloads

RangeVue Program Examples (1 KB) 12-07-2024

Two programs use the C1! SDI-12 instruction to measure the RangeVue-series sensors. One program is for the CR350 data logger and one program is for the CR1000X data logger. The program sets the Stage_Reference value to 15.25. This value needs to be changed to your stage reference value. Also, the SDI-12 address is entered as a constant with a value of 0. If the SDI-12 address of the sensor has been changed from the default value, this value needs to be changed to match the sensor address. The program sets the Sensor_Units variable to feet (option 1), which needs to be changed if using other units. See comments in the program for details.


This Product Replaced

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences