The CSIM11-ORP, manufactured by Wedgewood Analytical, measures oxidation reduction potential (ORP) of liquids. It can be submerged in water or inserted into tanks, pipelines, and open channels. The CSIM11-ORP is intended for non-pressurized systems and was not designed for applications above 30 psi. Please contact Campbell Scientific for recommendations on probes suitable for installations in pressurized pipes.
Read MorePlease note that this product has a six-month warranty.
The "-L" on a product model indicates that the cable length is specified at the time of order.
The CSIM11-ORP is similar to the CSIM11, but includes a 0.2-in. platinum band wrapped around the glass electrode, which allows the CSIM11-ORP to respond to the electron density in the fluid. It has a plunger-style pH glass electrode that allows the CSIM11-ORP to be mounted at any angle. The probe's porous polytetrafluoroethylene (PTFE) liquid junction is less susceptible to clogging as compared to conventional reference junctions.
A titanium ground rod runs inside the PPS outer body to eliminate ground loop errors. An internal amplifier boosts the signal, decreasing signal interference. The amplifier is powered by two internal lithium batteries, and thus does not require any current from the data logger. These batteries are designed to last the lifetime of the probe.
The reference solutions and bulb configuration are optimized for natural water applications. Alternate reference solutions and bulb configurations are available. Contact Campbell Scientific for pricing and availability.
Note: The CSIM11-ORP uses glass bulb technology which has a life expectancy of around 6 months to 2 years, depending on the conditions of the water.
Output | Analog |
ORP Range | -700 to +1100 mV |
Operating Temperature Range | 0° to 80°C |
Pressure Range | 0 to 30 psig |
Accuracy | ±0.1% (over full range) |
Impedance | < 1 Mohm (@ 25°C) |
Reference Cell | Single Junction KCl/AgCl |
Body Material | ABS |
Wetted Materials | ABS, polytetrafluoroethylene (PTFE), Viton, glass, titanium |
Cable Jacket Material | Polyurethane |
Response Time | 95% of reading (in 10 s) |
Drift | < 2 mV per week |
Internal Lithium Battery Lifetime | 5 years (life of probe) |
Diameter | 3.0 cm (1.2 in.) |
Length | 17.8 cm (7.0 in.) |
Weight | 0.5 kg (1 lb) with 4.57-m (15-ft) cable |
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Product | Compatible | Note |
---|---|---|
CR1000 (retired) | ||
CR1000X | ||
CR300 | ||
CR3000 (retired) | ||
CR310 | ||
CR350 | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) |
The CSIM11-ORP requires one differential analog input channel.
Number of FAQs related to CSIM11-ORP-L: 3
Expand AllCollapse All
Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:
If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.
If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.
Not every sensor has different cable termination options. The options available for a particular sensor can be checked by looking in two places in the Ordering information area of the sensor product page:
If a sensor is offered in an –ET, –ETM, –LC, –LQ, or –QD version, that option’s availability is reflected in the sensor model number. For example, the 034B is offered as the 034B-ET, 034B-ETM, 034B-LC, 034B-LQ, and 034B-QD.
All of the other cable termination options, if available, are listed on the Ordering information area of the sensor product page under “Cable Termination Options.” For example, the 034B-L Wind Set is offered with the –CWS, –PT, and –PW options, as shown in the Ordering information area of the 034B-L product page.
Note: As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model.
Many Campbell Scientific sensors are available with different cable termination options. These options include the following:
Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.
We've updated our privacy policy. Learn More