Services Available | |
---|---|
Repair | No |
Calibration | Yes |
Free Support | No |
The CS455 is a pressure transducer for for water level measurements in canals, wells, ponds, harbors, lakes, streams and tanks. It has a rugged titanium case that allows it to be used in saltwater and other harsh environments. The CS455 outputs either a digital SDI-12 or RS-232 signal to indicate observed pressure and temperature. This output can be read by many of our data loggers.
Read MoreThe "-L" on a product model indicates that the cable length is specified at the time of order.
The CS455 consists of a piezoresistive sensor and a temperature sensor housed in a titanium case. It has a rugged Hytrel cable that remains flexible, even under harsh environmental conditions. The cable incorporates a vent tube to compensate for atmospheric pressure fluctuations. The vent tube terminates inside a desiccant tube, which prevents water vapor from entering the inner cavity of the transducer.
The CS455 has several pressure range options and two accuracy options (see Ordering Info). The standard accuracy option provides ±0.1% FS TEB over the 0° to 60°C temperature range. The high accuracy option provides ±0.05% FS TEB over the 0° to 60°C temperature range and includes a calibration certificate. TEB is the combined errors due to nonlinearity, hysteresis, non-repeatability, and thermal effects over the compensated temperature range, per ISA S51.1. Please note that the high accuracy option is not available for the 0 to 2.9 psig range option.
Campbell Scientific offers the A150 Desiccated Case that allows the CS455 to be connected to a CWS900 Wireless Sensor Interface (for use in a wireless sensor network) or to be connected to a prewired enclosure (see Ordering Information).
Measurement Time | < 1.5 s |
Outputs | SDI-12 (version 1.3) 1200 bps; RS-232 9600 bps |
Resolution | 0.0035% FS |
Operating Temperature | -10° to +80°C |
Compensated Temperature | 0° to 60°C |
Temperature Accuracy | ±0.2°C |
Overpressure | 2 x pressure range |
Power Requirements | 6 to 18 Vdc |
Accuracy with Standard Accuracy Option | ±0.1% FS TEB (Includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range, per ISA S51.1.) |
Accuracy with High Accuracy Option | ±0.05% FS TEB (The high accuracy [±0.05% FS] option is not available for the 0 to 2.9 psig range option.) |
Cable Type | Hytrel Jacket, five conductor, 26 AWG |
NPT Fitting | 1/4-in. NPS |
Top Cone Material | Delrin |
Body Material | Titanium |
Element Material | Hastelloy |
Diameter | 2.13 cm (0.84 in.) |
Length | 21.34 cm (8.4 in.) |
Distance |
|
Weight without Cable | 0.11 kg (0.25 lb) |
Cable Weight | 0.421 kg/m (0.283 lb/ft) |
Weight | 0.211 kg (0.465 lb) for 25414 Weighted Nose Cone |
Power Consumption |
|
Quiescent | < 80 µA |
Measurement/Communication | 8 mA (1-s measurement) |
Maximum | 40 mA |
Pressure Measurement Range |
|
Option -2 | Up to 2.9 psig (20 kPa) |
Option -7 | Up to 7.25 psig (50 kPa) |
Option -14 | Up to 14.5 psig (100 kPa) |
Option -29 | Up to 29 psig (200 kPa) |
Option -72 | Up to 72.5 psig (500 kPa) |
Option -145 | Up to 145 psig (1000 kPa) |
Depth of Fresh Water Measurement Range |
|
Option -2 | Up to 2.0 m (6.7 ft) |
Option -7 | Up to 5.1 m (16.7 ft) |
Option -14 | Up to 10.2 m (33.4 ft) |
Option -29 | Up to 20.4 m (67 ft) |
Option -72 | Up to 50.9 m (167 ft) |
Option -145 | Up to 102 m (334.5 ft) |
Maximum Cable Length |
|
SDI-12 (1 sensor connected to a single port) | ~457 m (1500 ft) |
SDI-12 (10 sensors connected to a single port) | 60 m (200 ft) |
RS-232 | 60 m (200 ft) |
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR1000 (retired) | ||
CR10X (retired) | ||
CR200X (retired) | ||
CR206X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | ||
CR295X (retired) | ||
CR3000 (retired) | ||
CR500 (retired) | ||
CR5000 (retired) | ||
CR510 (retired) | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) | ||
CR9000X (retired) |
The CS455 can be used with the A150. The A150 is a small, self-contained junction box that allows the CS455 to be connected to a continuation cable, a prewired-enclosure connector, or a CWS900-series wireless-sensor connector. Connection to a CWS900-series interface allows the CS455 to be part of a wireless sensor network.
We've updated our privacy policy. Learn More
Update your cookie preferences. Update Cookie Preferences