CS120A Atmospheric Visibility Sensor
High-Performance Visibility Measurements
Competitive price
weather applications water applications energy applications gas flux and turbulence applications infrastructure applications soil applications

Overview

The CS120A uses tried-and-tested, infrared forward-scatter technology, and it uses the proven 42° scatter angle to report meteorological observable range (MOR) for fog and snow in the range of 5 to 75,000 m (16.4 to 246,063 ft). It combines a high specification with a very competitive price. The CS120A is ideal for stand-alone applications or in combination with automatic weather stations in road, aviation, solar-energy, and wind-energy environments.

For aviation applications, users can be assured that the CS120A complies with UK CAA, FAA, and ICAO guidance and meets or exceeds all recommendations and specifications. (This includes CAP437, CAP670, and CAP746.)

The CS120A is certified by Deutscher Wetterdienst as suitable for use to control wind turbine obstruction light systems as specified by 506/04, General Administrative Rules for the Identification of Aircraft Obstructions.

Read More

Benefits and Features

  • High performance sensor at a competitive price
  • Sensor design minimizes airflow disruption at measurement volume
  • Incorporates automatic dew and hood heaters for all-weather operation
  • Simple field calibration using optional calibration kit
  • Low power—suitable for remote application
  • Automatic status check for faults or window contamination
  • Type certified for aviation use by the German Meteorological Service, Deutscher Wetterdienst (DWD)

Images

Detailed Description

Compared to many such sensors, the CS120A design means that visibility is being measured in a relatively clean space because the position of the heads and body minimize disturbance of the airflow at the measurement volume.

The CS120A uses continuous high-speed sampling, which improves the accuracy of the measurements taken during mixed weather such as rain and hail, while providing reliable readings during more stable events such as fog and mist. High-speed sampling also allows the sensor to better respond to suddenly changing conditions.

The CS120A has several design features that keep its optics clean. Downward-facing optics minimize dirt and snow buildup. Low-powered heaters prevent the formation of dew, and a higher-powered heater prevents the formation of ice.

The sensor is very power efficient, drawing just 3 W during normal operation including the dew heaters; power can be reduced further by reducing the sample rate and manual control of the heaters.

Two configurable alarm outputs are provided and, via relays, these can drive external warning systems such as lights and foghorns. They can also be used to switch the intensity of wind turbine warning lights depending upon current visibility levels.

Specifications

Signal Type/Output RS-232, RS-485
Measurement Description Meteorological Observable Range (MOR)
Maximum Reported Visibility 100 km (62.1 mi)
Minimum Reported Visibility 5 m (16.4 ft)
Accuracy
  • ±8% at < 600 m (< 1968.5 ft)
  • ±10% at 600 to 10,000 m (1968.5 to 32,808.4 ft)
  • ±15% at 10,000 to 15,000 m (32,808.4 to 49,212.6 ft)
  • ±20% at 15,000 to 75,000 m (49,212.6 to 246,063 ft)
Resolution 1 m (3.3 ft)
Mounting Stainless-steel V-bolt bracket that attaches to a pole with a 32 to 52.5 mm (1.25 to 2 in.) outer diameter
Electronics Supply Voltage 7 to 30 Vdc
Total Unit Power < 3 W while sampling continuously (including dew heaters)
Standards Frangible masts are available to customer requirements to meet ICAO recommendations (typically placing the sample volume at 2.5 m [8.2 ft]).
Sensor Dimensions 540 x 640 x 246 mm (21.26 x 25.2 x 9.7 in.) including mount
Sensor Weight ~3 kg (6.6 lb) depending on mounting system

Optical/Pulse

LED Center Wavelength 850 nm
LED Spectral Bandwidth ±35 nm
Light Pulse Rate 1 kHz

Environmental

Operating Temperature Range -25° to +60°C (standard)
Extended Operating Temperature Range -40° to +70°C (This extended version is available as a special. Contact Campbell Scientific for more information.)
Operating Humidity Range 0 to 100%
Sensor Sealing Rated to IP66
Wind Speed Up to 60 m s-1
Sensor Heater Threshold
  • < 35°C (dew heater on)
  • > 40°C (dew heater off)
  • < 5°C (hood heater on)
  • > 15°C (hood heater off)

DSP & Dew Heaters

Power 2 x 0.6 W (total of 1.4 W) for dew heater
Typical Current Consumption @ 12 Vdc
  • 200 mA (continuous sampling, dew heaters active)
  • 110 mA (continuous sampling, dew heaters disabled)
  • 21 mA (no sampling, dew heaters disabled)
  • 200 mA (dew heaters active, RS-232 communications)

Hood Heater

Supply Voltage 24 V dc or ac
Power 2 x 30 W (total of 60 W)

Interface

Serial Interface RS-232 or RS-485, 8 bit data bytes, 1 stop bit
Serial Data Rates 1200 to 115,200 bps (38,400 bps default rate)

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
CR1000 (retired)
CR1000X
CR300
CR3000 (retired)
CR310
CR350
CR6
CR800 (retired)
CR850 (retired)

Downloads

CS125 and CS120A OS v.17 (555 KB) 08-06-2023

Campbell Scientific has introduced a new operating system, OS 17, for the CS120A visibility sensor and CS125 present weather sensor. It is backwards compatible and is easily installed on all CS120A and CS125 sensors (but not older CS120 sensors). OS 17 is available free of charge and can be downloaded here or supplied by email on request.

Upgrade to OS 17 is recommended.

View Update History

Frequently Asked Questions

Number of FAQs related to CS120A: 3

Expand AllCollapse All

  1. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  2. Not every sensor has different cable termination options. The options available for a particular sensor can be checked by looking in two places in the Ordering information area of the sensor product page:

    • Model number
    • Cable Termination Options list

    If a sensor is offered in an –ET, –ETM, –LC, –LQ, or –QD version, that option’s availability is reflected in the sensor model number. For example, the 034B is offered as the 034B-ET, 034B-ETM, 034B-LC, 034B-LQ, and 034B-QD.

    All of the other cable termination options, if available, are listed on the Ordering information area of the sensor product page under “Cable Termination Options.” For example, the 034B-L Wind Set is offered with the –CWS, –PT, and –PW options, as shown in the Ordering information area of the 034B-L product page.

    Note: As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model. 

  3. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • The –PT (–PT w/Tinned Wires) option is the default option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a data logger.
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note: The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.

Case Studies

Utah: Upgraded Roadside Weather Stations
The Utah Department of Transportation (UDOT) operates a network of roadside weather stations across the......read more
Portugal: Cloud Base and Visibility Sensors for Military Aviation
AUDIMOBIL recently installed an Automatic Weather Station in a Portuguese Military Air Base, to support......read more

This Product Replaced

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences